ASIO Monitoring
Enable monitoring while recording when using ASIO cards as recording source. If enabled the input audio is routed to the "Out1+2” output channels while recording is active (with a low latency). To activate this function, set the parameter:
The ASIO monitoring function is also definable individually for each working page with recording functions:
Working Page: | Parameter | Value (on/off) |
---|---|---|
All | …|MultiTrack|Settings|AsioMonitoring | 0,1 |
Record Page | …|MultiTrack|Settings|AsioMonitoring_Reporterbox | 0,1 |
Reporterbox Page | …|MultiTrack|Settings|AsioMonitoring_RecordPage | 0,1 |
MultiTrack Page | …|MultiTrack|Settings|AsioMonitoring_MultiTrack | 0,1 |
The three individual working page parameters have a higher priority, than the general "AsioMonitoring” parameters. This means, "AsioMonitoring” only works e.g. in the Reporterbox Page, if "AsioMonitoring_Reporterbox” has not been entered.