Broadcast Server
We strongly recommend to first use this version in a test environment before going productive with it. A stress test in a productive-like situation is needed in order to ensure the stability of this version.
Talk to our support team to get this version.
Component | Version |
---|---|
BCS.EXE BCSGUI.EXE BCS64.EXE BCSGUI64.EXE | 6.2.442.5 (Patch release) |
Dependencies
DigaSQL.dll 3.20.3503.0 or newer (recommended)
DigaSQL64.dll 3.20.3503.0 or newer (recommended) - for use with BCS64.exe
Fixed Issues
OIA-5550/CCD-44465,44480: BCS 32-bit could reach a semi-blocked state in which no new connections of SeplProtocol clients were accepted. This problem was present in all 6.x versions so far and it was triggered by two or more SeplProtocol clients to send out generic/broadcast messages at nearly the same time. Most requests for existing connections were still handled correctly, but BCS seemed to be semi-dead, nevertheless.
OIA-6238/CCD-44720: When a client tried to modify a program node, BCS started reading all the XML files of this program into memory - possibly crashing at some point. This was a new bug since the support of endpoint-stories in version 6.1.431.0.
CCD-44770/OIA-3506: The modifications in version 6.3.450.0 regardings the rights caused a problem, which was fixed. Now the two rights "Write to protected show" and "Change current show" are no longer applied if the user tries to modify nodes in the pool of a show and he has the right to write in "<Service name>\Pools".