Skip to main content
Skip table of contents

Broadcast Server

Component

Versions

BCS.EXE

BCSGUI.EXE

BCS64.EXE

BCSGUI64.EXE

6.2.443.4

6.3.457.2

Dependencies

  • DigaSQL.dll 3.20.3503.0 or newer (recommended)

  • DigaSQL64.dll 3.20.3503.0 or newer (recommended) - for use with BCS64.exe

Fixed Issues

  • Fixed issue linked to message "Buddy restart not possible" (CCD-45243)
    The function, which should check regularly, whether both sides of BCS buddies are running in master mode did not work correctly anymore. This was a new bug since version 6.0.400.0. As a consequence, it could happen that in such a setup either both servers were running in master mode or that terminating the right server did not work.

Only for 6.3 - Fixed Issues

  • When the send state of multiple elements was changed, BCS marked these elements in the resulting UpdateNodeTree notification as "no action for the fulltext index necessary". This was wrong, because BCSSearch can search for the send state very well and as a result the data in the fulltext index was not updated by BUS.

Only for 6.3 - New/Changes

  • Changed time computation (CCD-44854)
    BCS used the last element of a group with a real stop time to determine the stop time of a group - even if this element was completely overlapped by main elements, but did not have the Overlaid flag set. Now BCS takes the last stop time of all played elements in a group to determine the stop time of a group.

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.