There are two ways to provide TurboPlayer configuration data to the TurboPlayer Service:
-
Reference an existing TurboPlayer configuration by specifying the
ConfigurationandConfigurationHostparameters. TurboPlayer Service retrieves all required settings from the referenced TurboPlayer configuration. -
Define configuration parameters directly in TurboPlayer Service by not defining (or leaving empty) the
Configurationparameter and providing all required TurboPlayer settings directly in the service configuration.
1. Reference an existing TurboPlayer Configuration
|
Parameter name |
Description |
|
Configuration |
To enable communication with TurboPlayer, the service should use the TurboPlayer configuration settings through TurboPlayer configuration Name (e.g., Key Behavior
Access Requirements
Connection Details
GUI Number Check
|
|
ConfigurationHost |
Specifies the name of the workstation whose local registry contains the TurboPlayer configuration.
This ensures that the correct configuration is accessed, especially in distributed or networked environments. Default value:
|
|
GuiNumber |
Number of TurboPlayer GUI related to the configuration. GUI number of TurboPlayer (Settings/"the GUI number"). Warning! GUI number used by the service must be never equal to the GUI other numbers used by worked TurboPlayer instance. This cause TurboPlayer to frozen |
|
ReadOnly |
Default value:
|
|
Timeout |
TurboPlayer Engine connection & request timeout in milliseconds Default value:
|
2. Define those configuration parameter directly in TurboPlayer Service
If Configuration from above is not defined, the following TurboPlayer parameters can be directly configured in the TurboPlayer Service.
If a valid TurboPlayer configuration is found (via Configuration), all TurboPlayer-related settings from below are ignored. In this case, the configuration obtained from TurboPlayer takes precedence and will be used by the service.
|
|
|
|---|---|
|
CommunicationType |
Parameter is ignored if
|
|
EngineAddress |
Parameter is ignored if Used only with communication type "IP" IP address or resolvable name of the TurboPlayer engine |
|
TreeManagerPortRange |
Parameter is ignored if Used only with communication type "IP" Port range for Tree Manager as Low-High Default value:
|
|
RundownKernelPortRange |
Parameter is ignored if Used only with communication type "IP" Port range for Rundown Kernel as Low-High Default value:
|
|
UseGlobalNamespaceForMMF |
Parameter is ignored if Used only with communication type "MMF"
Default value:
|
|
Bcs |
Parameter is ignored if DigaSystem BCS name (not workstation name!) used by TurboPlayer to connect Default value:
|