DigAIRange
2Component | Version |
|---|---|
DigAIRange | 6.6.1012.2 |
Dependencies
DigaSQL.dll 3.23.3528.0 (recommended)
MultiRec4 4.10.364.0 or newer (recommended)
OnAIR TrackMixer 2.10.840.0 or newer (recommended)
Fixed Issues
Since build 6.0.917.3 or 6.1.932.0 there was misleading data behavior for some of the fields in the mask. Sometimes, old data as leftover from the last displayed content was displayed instead of an empty field. This affected the fields: jingle group and filler group in the general submask for a group, the output channel in the general submask and the cart priority in the cart submask. (CCD-45954/OIA-9764)
In the general submask the labels for the fields: output channel, function and distribution endpoints were not always correctly activated, depending on the content. (This affected only the English version.)
Fixes “When creating a new Program in DigAiRange without creating any jinglebanks, error messages such as "Node not found" appear in a BUS file check if the job is set to check for jingles.”
New/Changes
Support Drag&Drop of Endpoint Stories to OTMs SingleTrack and MultiTrack views. Now a single neutral element EPS stays closed once opened in OTM. Once an EPS or a Group type node is closed in DigAIRange the OTM item is displayed at the group header accordingly. (CCD-45276/OIA-10411)
Support D&D of EPS to OTMs SingleTrack - Update of OTM to Version 2.10.838.0 or higher is required. (CCD-45276/OIA-10411)
A feature for a very special video workflow has been implemented: if the global flag BroadcastSystem\PlayVideoInsteadOfMediaFile is set to TRUE and if an element with media type Audio references an additional video file in the medium list together with type “VIDEO” and one of the flags “.HIRES.” or “.LOWRES.” then DigAIRange will play this video file instead of the audio file when the user starts prelistening (e.g. with a middle mouse click). The used video player can be configured as usual in the settings, tab “Local”, “Video preview with…”.
When loading content from the upper show view into OnAIR TrackMixer via drag&drop it is possible now to select endpoint stories for loading. Hint: an adapted version of OTM is needed to handle this correctly and pick the right elements to be loaded. (CCD-45276/OIA-2821)
Prelistening for Groups, Stories, and Endpoint Stories (EPS):
It is now possible to prelisten to Groups, Stories, and Endpoint Stories (EPS) directly from the list view without needing to open them. The player appears immediately below the selected row, similar to the prelistening interface for single elements. For standard Groups and Stories, the system automatically plays the first available audio element. For Endpoint Stories (EPS), it targets the first element containing "TurboPlayer" as the designated endpoint. To support this workflow, the prelisten button columns, right-click context menu, and toolbar player button are now fully enabled for these element types.
(OIA-9919)Manually skipped elements should not be ignored on re-import of a show rundown. Until now, re-imported items were added again to the show plan (if destination element was manually skipped). Now they are kept as they were. (OIA-10110)
Added Accessibility features for DigaTree (Server selection view) and DigaGrid (Entries view) in DigAIRange. (OIA-9889)
Changed the used boost library to version 1.84 and OpenSSL to version 3.5. (OIA-9820)
When toggling off/on the info/preview lines the most recently selected entry in the list stays focused in the center of the visible range